Fire Resistance Calculator

Determine the minimum fire resistance period for structural elements per Approved Document B. Lookup Table A2 requirements by building height, purpose and element type.

Height of topmost floor above ground

Elements requiring protection

Fire protection cost per element

How We Calculate This

This calculator looks up the minimum fire resistance period from Approved Document B, Table A2 based on building parameters.

The lookup

Fire resistance = f(building purpose, height, element type, basement)

  • Up to 5m: 30 mins (non-residential)
  • 5-18m: 60 mins
  • 18-30m: 90 mins
  • Over 30m: 120 mins
  • Residential (flats): 60 mins minimum at all heights per AD B Vol 1
  • Basements: 60 mins (≤10m), 90 mins (>10m)